WIRING DIAGRAMS
Figure 6. W.D. for 1.5, 2, & 2.5 Ton Models
7110050
WIRING DIAGRAM
NOTES:
FIELD WIRING
LEGEND:
LOW VOLTA GE
HIGH VOLTA GE
CRANKCASE
HEATER
(OPTIONAL)
3
1
2
START
CAPAC
to”Con
capacitor
to T2 on
capacitor
to “Hon
capacitor
START
RELAY
Single Phase
1. Couper le courant avant de faire letretien.
2. Employez uniquement des conducteurs
en cuivre.
3. Ne convient pas aux installations
de plus de 150 volt a la terre.
Split System Air Conditioner (Outdoor Section)
1. Disconnect all power before servicing.
2. For supply connections use copper conductors only.
3. Not suitable on systems that exceed 150 volts to ground.
4. For replacement wires use conductors suitable for 105 deg C.
5. For ampacities and overcurrent protection, see unit rating plate..
6. Connect to 24 vac/40ca/class 2 circuit. See furnace/airhandler installation
instructions for control circuit and optional relay/transformer kits.
7. Anti-Shor t Cycle Ti mer (ASCT) may or may not be installed in the unit. If desired,
ASCT is factory installed on select models only or may be field installed as shown using
manufacturer’s approved kit. If not present, connect Yellow and Black wires per Note 6.
8. DO NOT use a Hard Start Kit on a model with a PTCR installed .
CC - Contactor Coil
CCH - Crankcase Heater
HPS - High Pressure Switch
208/230V
CC
ASCT
ASCT
(SEE NOTE 7)
H
C
F
CCH
(OPTIONAL)
R
C
S
S
C
R
L2
T2
COMPRESSOR
CONTACTS
L1
T1
PTCR(If equipped)
CO MPRESSOR
OUTDOOR FAN
MOTOR
24 VOLT FIELD
CONNECTIONS
HPS
T1
T3
T2
HPS
WIRE NUT
GROUNDING
SCREW
L1 L2
GND
T1
T2
L1
L2
OUTDOOR
FAN MOTOR
C
S
DUAL
CAPACITOR
R
CONTACTOR
C
S
R
H
C
F
ORANGE
BLUE
BLACK
PTCR
BLACK
BLACK
YELLOW/
BLACK
BLACK
RED
BLACK
YELLOW
BLACK
SEE NOTE 6
ASCT
(SEE
NOTE 7)
YELLOW
YELLOW
RED
BLACK
YELLOW