Kelvinator JS4BD030KB Installation Guide Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
13
Table 5. Charging Table for S4BD-030 Series (2.5 Ton Units) - Orifice Matches
Suct.
Press.
OUTDOOR TEMPERATURE (°F)
70 75 80 85 90 95 100 105
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
126 278 132
128
280 135
303 137
130 281 138
305 140
328 141
132
283 141
306 143
330 144
354 145
134 284 145
308 146
331 147
355 148
379 149
136 309 149
333 150
357 151
380 152
404 154
138 334 153
358 154
382 156
406 157
429 158
140 360 157
384 159
407 160
431 161
454 162
142 361 161 385 162
409 163
432 164
456 165
144 387 164 411 166
434 167
457 168
146 412 168 436 170
460 171
148 438 172 462 173
150 464 176
152
Table 6. Charging Table for S4BD-036 Series (3 Ton Units) - Orifice Matches
Suct.
Press.
OUTDOOR TEMPERATURE (°F)
70 75 80 85 90 95 100 105
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
124 261 137
126
263 141
287 140
128 265 144
288 143
312 142
130
266 147
290 146
313 146
337 145
132 268 150
292 149
315 149
339 148
362 147
134 293 153
317 152
340 152
364 151
387 150
136 318 155
342 154
365 154
389 153
413 152
138 344 158
367 157
390 157
414 156
438 155
140 345 161 369 160
392 160
416 159
439 158
142 370 163 394 163
417 162
441 162
144 396 166 419 165
442 165
146 421 168 444 168
148 446 171
150
LEGEND
Shaded boxes indicate flooded conditions.
Rated design values. The suction pressure will be lower than design value if outdoor air flow, entering
dry bulb, or entering wet bulb temperatures are lower than design.
NOTES:
1. All pressures are listed psig and all temperatures in °F
2. Discharge temperatures GREATER than charted values indicate an UNDERCHARGED system.
3. Discharge temperatures LESS than charted values indicate an OVERCHARGED system.
Page view 12