15
Suct.
Press.
OUTDOOR TEMPERATURE (°F)
70 75 80 85 90 95 100 105
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
121 264 149
123
265 153
289 153
125 267 156
290 157
313 157
127
268 159
291 160
314 161
338 161
129 270 162
293 163
316 164
339 165
362 165
131 294 166
317 167
340 168
363 169
387 169
133 319 170
342 171
365 172
388 173
411 173
135 343 174
366 175
389 176
412 177
435 178
137 345 177 368 178
391 179
414 180
437 181
139 369 181 392 182
415 183
438 184
141 394 185 417 186
440 187
143 418 189 441 190
145 442 193
147
Table 9. Charging Table for S4BD-060 Series (5 Ton Units) - Orifice Matches
LEGEND
Shaded boxes indicate flooded conditions.
Rated design values. The suction pressure will be lower than design value if outdoor air flow, entering
dry bulb, or entering wet bulb temperatures are lower than design.
NOTES:
1. All pressures are listed psig and all temperatures in °F
2. Discharge temperatures GREATER than charted values indicate an UNDERCHARGED system.
3. Discharge temperatures LESS than charted values indicate an OVERCHARGED system.